Main Unit |
Repeatability |
Better than 1% |
Accuracy |
Better than ±1%for velocity above 0.6ft/s |
Velocity |
0.5s |
Display |
LCD with backlight 2*20leters
Display instantaneous flow rate, accumulated flow rate(positive, negative
and net rates),velocity, time, analog inputs,etc. |
Units |
English(U.S) or metric |
Signal Outputs |
Current output: 4-20mA or 0-20mA. Impedance 0-1k. Accuracy 0.1% |
OCT output: pulse signal for accumulated flow rate(positive, negative
and net rates); frequency signal for instantaneous flow rate(0~9999Hz selectable) |
Relay: able to output 20 signals, such as no signal,revers flow, etc. |
Sound alarm |
Signal Inputs |
5 channel analog signal inputs
(for signals such as temperature, pressure, liquid level,etc.) |
Communication Interface |
RS-232,RS-485(optional)
GPRS/GSM module for networking, remote monitoring and remote
control(for model UFM-100FNB only) |
Enclosure |
Protection Class: IP65(NEMA 4X)
Explosive Proof Class: ExdⅡBT4(for model UFM-100F2B only) |
Liquids |
Liquid Types
Liquid Temp |
Virtually all commonly used liquids(full pipe) |
32F~212F (0℃~100℃) |
Pipe |
Suspension concentration
Pipe Size |
<1%, particle size smaller than 75um |
1"~240"(DN30~DN6000mm) |
Pipe Material |
All metals, most plastics, fiber glass, etc. Allow pipe liner |
Straight Pipe Section |
Longer than 15D, there D is pipe diameter. If a pump is near, the straight
pipe section following the pump should be >30D |
Environment |
Temperature
Humidity |
Main unit :0F~176F(-30℃~80℃) |
Transducer: -40F~212F(-40℃~100℃)
Main unit: 85%RH |
Transducer: water-immersible, water depth less than 10'(3m) |
Power |
AC: 110V/220V, or DC :8VDC-36VDC |
Weight |
Teren-UFM-100F:5lb(2.5kg) |